![]() ![]() Manually excluded samples and injections are listed in the FLIIMP report in the section "Pre-processing". After choosing a different sample in the list, and combing back to the sample with excluded injections, these will be marked in red in the graphic display panels. To exclude injections 3 and 4 of the current sample, enter 3 and 4 separated by a space character in the input box. If no sample is to be excluded, a value "-1" is displayed in the text entry box. In the Injections line below, it is possible to exclude specific injections from the processing. Using the buttons "Exclude all" and "Include all", it is possible to set all samples in the list as excluded/included. When the tickbox is checked, a "X" will appear in the list in front of an excluded sample. Using the checkmark "Exclude sample from processing" it is possible to disregard the currently selected sample from analysis. Injection nr.Ĭlicking on a list item will display the injections of a sample. Injection number (top) and a selected isotope parameter from the Parameter drop-down below vs. The figure panels to the right show box-and-whisker plots of H2O vs. The table shows each identified sample by its "Identifier 1" value, them mean H2O concentration (in ppmv), and the standard deviation based on all samples. In the second step, the data files for the selected period are loaded, and displayed for screening and selection. Path settings are saved automatically to the file "FLIIMP_settings.mat" in your home directory ($HOME on linux/mac systems). ![]() After clicking, please check the matlab command window for error messages or warnings. The button "Next >" advances to the second step. The settings are saved and loaded across all three steps of the calibration, not for each step separately. ![]() HKDS2038/IsotopeData/HKDS2038_IsoWater_20180912_120312.csvĪt any point, the settings can be saved to a. The search path for files is combined from the input file path, the instrument, and the time range, for example If only one date is given, either all files from that day (YYYYMMDD) or if a specific date with HHMMSS is given, that specific time will be looked for. ![]() If a range is given, all files that fall within the time period will be loaded. If choosing time range, only a date in format YYYYMMDD_HHMMSS needs to be given. Next, either a time range or specific files are selected. The instrument on which the liquid samples were measured is chosen from the pulldown list "Instrument". The base output file path where the new output folder will be created is specified in the second entry field. The Input file path for all injection files is specified in the first entry field.įLIIMP creates a report on the calibrated data in HTML format within a new subfolder. The example is using calls to the routine FLIIMP_batch.mįor further details, see the comments within the files.įLIIMP has 3 windows, that have to be completed in a fixed sequence.įLIIMP reads in the injection files from an instrument for a particular time, time range, or day. Path settings need to be adjusted to your computer. (optional) copy the script FLIIMP.sh to your computer to start FLIIMP with a double click. Get the current code from the FLIIMP git repository ![]()
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |